Effect of Source Impedance on Converters MCQ Quiz - Objective Question with Answer for Effect of Source Impedance on Converters - Download Free PDF
Last updated on Jun 26, 2025
Latest Effect of Source Impedance on Converters MCQ Objective Questions
Effect of Source Impedance on Converters Question 1:
For high power application the type of switched mode power supply used is:
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 1 Detailed Solution
Explanation:
Full Bridge Converter
Definition: A full bridge converter is a type of switched-mode power supply (SMPS) topology widely used in high-power applications. It is designed to efficiently convert electrical energy from one form to another, typically stepping up or stepping down DC voltage. The full bridge converter uses four switching devices (such as MOSFETs or IGBTs) arranged in a bridge configuration to transfer energy from the input to the output via a transformer. The primary advantage of this topology is its ability to handle higher power levels with improved efficiency.
Working Principle:
In a full bridge converter, the input DC voltage is applied across the primary winding of a transformer using four switches arranged in a full-bridge configuration. By alternately turning on and off pairs of switches, the converter generates an AC waveform at the transformer primary. This AC waveform is then stepped up or down by the transformer and rectified on the secondary side to produce the desired DC output voltage.
The switching sequence ensures that the transformer core operates efficiently, avoiding saturation and minimizing losses. The use of a transformer also provides isolation between the input and output, which is critical for safety and noise reduction in many applications.
Advantages:
- Capable of handling high power levels, making it suitable for industrial and commercial applications.
- Provides electrical isolation between input and output through the use of a transformer.
- High efficiency due to reduced switching losses and optimized transformer operation.
- Flexibility in stepping up or stepping down voltage levels using the transformer turns ratio.
- Supports bidirectional power flow when combined with appropriate control strategies.
Disadvantages:
- Increased complexity due to the requirement of four switches and associated control circuitry.
- Higher cost compared to simpler topologies like flyback or push-pull converters.
- Requires precise control of switching to avoid issues like shoot-through or transformer saturation.
Applications:
- High-power industrial power supplies.
- Electric vehicle chargers.
- Uninterruptible power supplies (UPS).
- Telecommunication power systems.
- Renewable energy systems, such as solar inverters and wind turbine controllers.
Correct Option Analysis:
The correct option is:
Option 1: Full bridge converter
The full bridge converter is the preferred choice for high-power applications due to its ability to handle large amounts of power efficiently and reliably. The use of four switches in a bridge configuration allows for effective energy transfer and voltage transformation through a transformer. Additionally, the inherent electrical isolation provided by the transformer enhances safety and noise immunity, making it ideal for demanding industrial and commercial environments. Its versatility and performance advantages make it the go-to topology for high-power SMPS designs.
Additional Information
To further understand the analysis, let’s evaluate the other options:
Option 2: Push-pull converter
The push-pull converter is another SMPS topology that uses two switches to alternately drive the primary winding of a center-tapped transformer. While it is suitable for medium power applications, it is not ideal for high-power scenarios due to limitations such as transformer core saturation and increased losses in the center-tapped winding. Additionally, the push-pull topology is less efficient than the full bridge converter at higher power levels, making it less suitable for demanding applications.
Option 3: Flyback converter
The flyback converter is a simple and cost-effective SMPS topology that uses a single switch and a transformer to convert voltage levels. It is primarily used in low to medium power applications due to its simplicity and low component count. However, it is not well-suited for high-power applications because of limitations like higher switching losses, reduced efficiency, and increased stress on components. The flyback topology is more commonly found in applications such as mobile chargers, LED drivers, and small power supplies.
Option 4: Half bridge converter
The half bridge converter is a simplified version of the full bridge converter, using only two switches to drive the transformer. While it is more efficient and less complex than the push-pull topology, it is still not as capable as the full bridge converter for handling very high power levels. The half bridge converter is typically used in medium power applications where cost and complexity need to be balanced with performance requirements.
Conclusion:
The full bridge converter stands out as the most suitable topology for high-power applications due to its superior efficiency, ability to handle large power levels, and inherent electrical isolation. While other topologies like push-pull, flyback, and half bridge converters have their own advantages in specific scenarios, they are not as effective as the full bridge converter for demanding high-power designs. Engineers often choose the full bridge topology for applications requiring reliable and efficient power conversion at elevated power levels.
Effect of Source Impedance on Converters Question 2:
For the same load, if the phase sequence of a three-phase supply changes, then:
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 2 Detailed Solution
Explanation:
Phase Sequence in Three-Phase Systems
Definition: The phase sequence (or phase rotation) in a three-phase system refers to the order in which the three phases (commonly labeled as A, B, and C) reach their respective maximum positive values. This sequence can be either ABC or ACB, and it is crucial for the correct operation of three-phase equipment, especially motors and other rotating machinery.
Working Principle: In a three-phase system, three sinusoidal voltages of equal magnitude and frequency are generated, with each voltage phase-shifted by 120 degrees from the others. The standard phase sequence ensures that the voltages reach their peak values in a specific order (e.g., A first, then B, then C). If the phase sequence is changed (e.g., from ABC to ACB), the direction of rotation of the magnetic field in motors will reverse, which can cause the motor to run in the opposite direction.
Correct Option Analysis:
The correct option is:
Option 3: Phase current changes by angle but not by magnitude.
This option correctly describes the effect of changing the phase sequence on the phase currents in a three-phase system. When the phase sequence is altered, the phase currents will shift in phase angle by 120 degrees, but their magnitudes will remain unchanged. This is because the phase sequence change does not affect the amplitude of the sinusoidal currents, only their relative timing.
Detailed Explanation:
In a three-phase system, the voltage and current waveforms are typically represented as:
Original Phase Sequence (ABC):
- Phase A: VA(t) = Vmsin(ωt)
- Phase B: VB(t) = Vmsin(ωt - 120°)
- Phase C: VC(t) = Vmsin(ωt - 240°)
Here, Vm is the peak voltage, ω is the angular frequency, and t is time.
When the phase sequence changes from ABC to ACB, the voltage waveforms become:
- Phase A: VA(t) = Vmsin(ωt)
- Phase C: VC(t) = Vmsin(ωt - 120°)
- Phase B: VB(t) = Vmsin(ωt - 240°)
Consequently, the phase currents will also shift in phase angle by 120 degrees, but their magnitudes will remain the same. This shift in phase angle is crucial for devices that rely on the direction of the rotating magnetic field, such as induction motors, as it will cause them to rotate in the opposite direction.
Additional Information
To further understand the analysis, let’s evaluate the other options:
Option 1: Magnitude of phase power is changed.
This option is incorrect because the magnitude of the phase power in a balanced three-phase system does not depend on the phase sequence. Phase power is primarily determined by the voltage, current, and power factor. Changing the phase sequence only affects the direction of rotation of the magnetic field, not the magnitude of the power.
Option 2: Magnitude of phase current is changed.
This option is also incorrect because changing the phase sequence does not affect the magnitude of the phase currents. The phase currents will have the same amplitude but will be phase-shifted by 120 degrees.
Option 4: Total power consumed will change.
This option is incorrect because the total power consumed in a balanced three-phase system is the sum of the power consumed in each phase. Since the power in each phase remains unchanged regardless of the phase sequence, the total power consumed will also remain unchanged.
Conclusion:
Understanding the impact of phase sequence on three-phase systems is crucial for the correct operation of equipment, especially motors. Changing the phase sequence results in a phase shift of the currents by 120 degrees, but their magnitudes remain unchanged. This phase shift can reverse the direction of rotation of motors, which is essential information for ensuring the proper functioning of three-phase machinery.
Effect of Source Impedance on Converters Question 3:
For the 3ϕ full converter having resistive load, the ripple frequency f ripple is __________.
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 3 Detailed Solution
Concept:
Ripple Frequency: Ripple frequency is the output frequency of a converter which is some integral multiple of the supply frequency.
\(\)\(f_{ripple}\)= n × fs
\(f_{ripple}\)= Ripple frequency
fs = Supply frequency
n = No. of pulses in the time period
Calculation:
The 3ϕ full converter has 6 no. of pulses in the time period of the output waveform.
fs = 50 Hz
\(f_{ripple}\)= 6 × 50
\(f_{ripple}\)= 300 Hz
Additional Information The 1ϕ full converter has 2 no. of pulses in the time period of the output waveform.
So, \(f_{ripple}\) = 2 × fs
\(f_{ripple}\)= 2 × 50
\(f_{ripple}\) = 100 Hz
Effect of Source Impedance on Converters Question 4:
Firing angle of the use for __________
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 4 Detailed Solution
The correct answer is 2) To control the on-off timing of SCR.
Concept:
- The firing angle refers to the phase angle at which the gate signal is applied to a thyristor, specifically the silicon-controlled rectifier (SCR). The firing angle determines when the SCR turns on and conducts current.
- By adjusting the firing angle, the on-off timing of the SCR can be controlled. When the firing angle is zero degrees (fully conducting), the SCR turns on at the beginning of each cycle of the applied alternating current (AC) waveform. As the firing angle increases, the SCR turns on later in the AC cycle, resulting in a reduced conduction time and a lower average output voltage.
- By varying the firing angle over a range from 0 to 180 degrees, the SCR can be triggered at different points within each AC cycle, allowing for control of the power delivered to the load. This control is essential for applications such as motor speed control, light dimming, and power regulation.
Effect of Source Impedance on Converters Question 5:
A single phase full converter delivers power to a resistive load R. For an AC source voltage of Vs, the average output voltage Vo is given by (where α is firing angle):
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 5 Detailed Solution
1ϕ full converter with resistive load
Case 1: During +ve half cycle (α to π)
T1 and T2 are forward-biased.
Vo = Vs
Case 2: During -ve half cycle (π+α to 2π)
T3 and T4 are forward-biased.
Vo = -Vs
The waveform is given below:
The average output voltage is given by:
\(V_{o(avg)}={1\over 2π}({\int_{α}^{π}V_s\space sin\omega t\space d\omega t}+{\int_{π +α}^{2π}-V_s\space sin\omega t\space d\omega t})\)
\(V_{o(avg)}={V_s\over 2\pi}(cos\alpha-cos\pi+cos2\pi+cos(\pi+\alpha))\)
\(V_{o(avg)}={V_s\times 2\over 2\pi}(1+cos\alpha)\)
\(V_{o(avg)}={V_s\over \pi}(1+cos\alpha)\)
Here, Vs is the RMS value.
The average output voltage in terms of the maximum value is:
\(V_{o(avg)}={\sqrt{2}V_s\over \pi}(1+cos\alpha)\)
Top Effect of Source Impedance on Converters MCQ Objective Questions
A single phase full converter feeds power to RLE load with R = 8Ω, L = 8 mH and E = 46.42 V, the ac source voltage is 230 V, 50 Hz, for continuous conduction. Find the average value of load current for a firing angle delay of 45°
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 6 Detailed Solution
Download Solution PDFThe average output voltage of a 1-ϕ full converter with RLE loads for continuous conduction.
\({V_0} = \frac{{2{V_m}}}{\pi }\cos \alpha\)
Vm = √2 Vrms = √2 x 230 V
V0\(= \frac{{2\; \times \;√ 2 \cdot 230}}{\pi }\cos 45^\circ\)
V0 = 146.42 V
V0 = E + I0R
\({I_0} = \frac{{{V_0} - E}}{R}\)
\(= \frac{{146.42 - 46.42}}{8}\)
I0 = 12.50 A
A single-phase, full-bridge, fully controlled thyristor rectifier feeds a load comprising a 10 Ω resistance in series with a very large inductance. The rectifier is fed from an ideal 230 V, 50 Hz sinusoidal source through cables which have negligible internal resistance and a total inductance of 2.28 mH. If the thyristors are triggered at an angle α = 45°, the commutation overlap angle in degree (rounded off to 2 decimal places) is _______
Answer (Detailed Solution Below) 4.51 - 5.10
Effect of Source Impedance on Converters Question 7 Detailed Solution
Download Solution PDFConcept:
In a single-phase full wave rectifier with source inductance is given by,
\({V_0} = \frac{{2{V_m}}}{\pi }\cos \alpha - \frac{{2\omega {L_s}}}{\pi }{I_0}\)
Average output current \({I_0} = \frac{{{V_0}}}{R}\)
\({I_0} = \frac{{{V_m}}}{{2\omega {L_s}}}\left[ {\cos \alpha - \cos \left( {\alpha + \mu } \right)} \right]\)
Where, Vm is the maximum value of supply voltage
α is the firing angle
μ is the overlapping angle
Ls is the source inductance
R is the load resistance
Calculation:
Given that, supply voltage (Vrms) = 230 V
Firing angle (α) = 45°
Source inductance (Ls) = 2.28 mH
Load resistance (R) = 10 Ω
Frequency (f) = 50 Hz
The average output voltage is
\({V_0} = {I_0}\left( {10} \right) = \frac{{2 \times 230 \times \sqrt 2 }}{\pi }\cos 45^\circ - \frac{{2\pi \times 2 \times 50 \times 2.28 \times {{10}^{ - 3}}}}{\pi }{I_0}\)
⇒ I0 = 14.003 A
\({I_0} = \frac{{{V_m}}}{{2\omega {L_s}}}\left[ {\cos \alpha - \cos \left( {\alpha + \mu } \right)} \right]\)
\( \Rightarrow 14.003 = \frac{{230 \times \sqrt 2 }}{{2 \times 2\pi \times 50 \times 2.28 \times {{10}^{ - 3}}}}\left[ {\cos 45^\circ - \cos \left( {45 + \mu } \right)} \right]\)
⇒ μ = 4.8°The figure below shows an uncontrolled diode bridge rectifier supplied from a 220 V, 50 Hz, 1-phase ac source. The load draws a constant current I0 = 14 A. The conduction angle of the diode D1 in degrees (rounded off to two decimal places) is ________.
Answer (Detailed Solution Below) 220 - 230
Effect of Source Impedance on Converters Question 8 Detailed Solution
Download Solution PDFConcept:
The small inductance connected with supply work as a source inductance Due to this inductance, there will be overlapping takes place between two diodes. As a result, this will cause an overlap angle 'μ'.
During overlap period, both diode D1 & D2 will conduct.
Calculation:
The output voltage (V0) & current waveform is shown below,
Output voltage in terms of load current is given by,
\(\rm V_0 = \frac{2 V_m}{\pi} \cos (α) - 4 f L_s I_0\)
For diode α = 0°,
\(⇒ \rm V_0 = \frac{2 \times 220\sqrt 2}{\pi}- 4 \times 50 \times 10 \times 10^{-3} \times 14\)
⇒ V0 = 170.06 V
In terms of overlap angle,
\(V_0 = \frac{V_m}{\pi} [\cos \alpha + \cos (\alpha + μ )]\)
\(⇒ 170.06 = \frac{220\sqrt 2}{\pi} [ 1 + \cos μ]\)
⇒ μ = 44.17°
Since, for an overlap angle of μ, all four diodes conduct & each diodes conducts for (180 + μ) degree.
So,
conduction angle (γ) = 180 + μ = 180 + 44.17
γ = 224.17°
For the 3ϕ full converter having resistive load, the ripple frequency f ripple is __________.
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 9 Detailed Solution
Download Solution PDFConcept:
Ripple Frequency: Ripple frequency is the output frequency of a converter which is some integral multiple of the supply frequency.
\(\)\(f_{ripple}\)= n × fs
\(f_{ripple}\)= Ripple frequency
fs = Supply frequency
n = No. of pulses in the time period
Calculation:
The 3ϕ full converter has 6 no. of pulses in the time period of the output waveform.
fs = 50 Hz
\(f_{ripple}\)= 6 × 50
\(f_{ripple}\)= 300 Hz
Additional Information The 1ϕ full converter has 2 no. of pulses in the time period of the output waveform.
So, \(f_{ripple}\) = 2 × fs
\(f_{ripple}\)= 2 × 50
\(f_{ripple}\) = 100 Hz
The frequency of ripple in the output voltage of a three phase controlled bridge rectifier depends on
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 10 Detailed Solution
Download Solution PDFThe frequency of ripple in the output voltage of a three-phase controlled bridge rectifier depends on the supply frequency. The output frequency is
f0 = n fS
Where n is the number of pulses in the output of the converter and fs is the supply frequency
Note: Ripple factor depends on the firing angle, load inductance, and resistance.A single phase full converter delivers power to a resistive load R. For an AC source voltage of Vs, the average output voltage Vo is given by (where α is firing angle):
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 11 Detailed Solution
Download Solution PDF1ϕ full converter with resistive load
Case 1: During +ve half cycle (α to π)
T1 and T2 are forward-biased.
Vo = Vs
Case 2: During -ve half cycle (π+α to 2π)
T3 and T4 are forward-biased.
Vo = -Vs
The waveform is given below:
The average output voltage is given by:
\(V_{o(avg)}={1\over 2π}({\int_{α}^{π}V_s\space sin\omega t\space d\omega t}+{\int_{π +α}^{2π}-V_s\space sin\omega t\space d\omega t})\)
\(V_{o(avg)}={V_s\over 2\pi}(cos\alpha-cos\pi+cos2\pi+cos(\pi+\alpha))\)
\(V_{o(avg)}={V_s\times 2\over 2\pi}(1+cos\alpha)\)
\(V_{o(avg)}={V_s\over \pi}(1+cos\alpha)\)
Here, Vs is the RMS value.
The average output voltage in terms of the maximum value is:
\(V_{o(avg)}={\sqrt{2}V_s\over \pi}(1+cos\alpha)\)
A half-wave, controlled rectifier with a purely resistive load has delay \(\alpha =\frac{\pi}{3}\), Calculate form factor.
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 12 Detailed Solution
Download Solution PDFConcept-
If a gate signal is applied to the SCR at 𝜔t=α, where α is the delay (firing or triggering) angle. The average (dc) voltage across the load resistor is
\({V_{dc}} = \frac{{{V_m}}}{{2\pi }}(1 + \cos \alpha )\)
The rms voltage Across the Resistor is
\({V_{rms}} = \frac{{{V_m}}}{2}\sqrt {\frac{1}{\pi }\left( {\pi - \alpha + \frac{{\sin 2\alpha }}{2}} \right)} \)
FORM factor for Rectifier is given by
\(FF = \frac{{{V_{rms}}}}{{{V_{dc}}}}\)
Solution:
given \(\alpha = \frac{\pi }{3}\)
\({V_{rms}} = \frac{{{V_m}}}{2}\sqrt {\frac{1}{\pi }\left( {\pi - \frac{\pi }{3} + \frac{{\sin \frac{{2\pi }}{3}}}{2}} \right)} \Rightarrow \)
Solution:
Given:
α = π/3
\(FF = \frac{{\frac{{{V_m}}}{2}\sqrt {\frac{1}{\pi }\left( {\pi - \frac{\pi }{3} + \frac{{\sin \frac{{2\pi }}{3}}}{2}} \right)} }}{{\frac{{{V_m}}}{2}\left( {1 + \cos \frac{\pi }{3}} \right)}}\)
\(= \frac{{\pi \left\{ {\sqrt {\frac{1}{\pi }\left( {\frac{{2\pi }}{3} + \frac{{\sin 120}}{2}} \right)} } \right\}}}{{1 + \frac{1}{2}}}\)
= 1.878 ≃ 1.9For high power application the type of switched mode power supply used is:
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 13 Detailed Solution
Download Solution PDFExplanation:
Full Bridge Converter
Definition: A full bridge converter is a type of switched-mode power supply (SMPS) topology widely used in high-power applications. It is designed to efficiently convert electrical energy from one form to another, typically stepping up or stepping down DC voltage. The full bridge converter uses four switching devices (such as MOSFETs or IGBTs) arranged in a bridge configuration to transfer energy from the input to the output via a transformer. The primary advantage of this topology is its ability to handle higher power levels with improved efficiency.
Working Principle:
In a full bridge converter, the input DC voltage is applied across the primary winding of a transformer using four switches arranged in a full-bridge configuration. By alternately turning on and off pairs of switches, the converter generates an AC waveform at the transformer primary. This AC waveform is then stepped up or down by the transformer and rectified on the secondary side to produce the desired DC output voltage.
The switching sequence ensures that the transformer core operates efficiently, avoiding saturation and minimizing losses. The use of a transformer also provides isolation between the input and output, which is critical for safety and noise reduction in many applications.
Advantages:
- Capable of handling high power levels, making it suitable for industrial and commercial applications.
- Provides electrical isolation between input and output through the use of a transformer.
- High efficiency due to reduced switching losses and optimized transformer operation.
- Flexibility in stepping up or stepping down voltage levels using the transformer turns ratio.
- Supports bidirectional power flow when combined with appropriate control strategies.
Disadvantages:
- Increased complexity due to the requirement of four switches and associated control circuitry.
- Higher cost compared to simpler topologies like flyback or push-pull converters.
- Requires precise control of switching to avoid issues like shoot-through or transformer saturation.
Applications:
- High-power industrial power supplies.
- Electric vehicle chargers.
- Uninterruptible power supplies (UPS).
- Telecommunication power systems.
- Renewable energy systems, such as solar inverters and wind turbine controllers.
Correct Option Analysis:
The correct option is:
Option 1: Full bridge converter
The full bridge converter is the preferred choice for high-power applications due to its ability to handle large amounts of power efficiently and reliably. The use of four switches in a bridge configuration allows for effective energy transfer and voltage transformation through a transformer. Additionally, the inherent electrical isolation provided by the transformer enhances safety and noise immunity, making it ideal for demanding industrial and commercial environments. Its versatility and performance advantages make it the go-to topology for high-power SMPS designs.
Additional Information
To further understand the analysis, let’s evaluate the other options:
Option 2: Push-pull converter
The push-pull converter is another SMPS topology that uses two switches to alternately drive the primary winding of a center-tapped transformer. While it is suitable for medium power applications, it is not ideal for high-power scenarios due to limitations such as transformer core saturation and increased losses in the center-tapped winding. Additionally, the push-pull topology is less efficient than the full bridge converter at higher power levels, making it less suitable for demanding applications.
Option 3: Flyback converter
The flyback converter is a simple and cost-effective SMPS topology that uses a single switch and a transformer to convert voltage levels. It is primarily used in low to medium power applications due to its simplicity and low component count. However, it is not well-suited for high-power applications because of limitations like higher switching losses, reduced efficiency, and increased stress on components. The flyback topology is more commonly found in applications such as mobile chargers, LED drivers, and small power supplies.
Option 4: Half bridge converter
The half bridge converter is a simplified version of the full bridge converter, using only two switches to drive the transformer. While it is more efficient and less complex than the push-pull topology, it is still not as capable as the full bridge converter for handling very high power levels. The half bridge converter is typically used in medium power applications where cost and complexity need to be balanced with performance requirements.
Conclusion:
The full bridge converter stands out as the most suitable topology for high-power applications due to its superior efficiency, ability to handle large power levels, and inherent electrical isolation. While other topologies like push-pull, flyback, and half bridge converters have their own advantages in specific scenarios, they are not as effective as the full bridge converter for demanding high-power designs. Engineers often choose the full bridge topology for applications requiring reliable and efficient power conversion at elevated power levels.
For the same load, if the phase sequence of a three-phase supply changes, then:
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 14 Detailed Solution
Download Solution PDFExplanation:
Phase Sequence in Three-Phase Systems
Definition: The phase sequence (or phase rotation) in a three-phase system refers to the order in which the three phases (commonly labeled as A, B, and C) reach their respective maximum positive values. This sequence can be either ABC or ACB, and it is crucial for the correct operation of three-phase equipment, especially motors and other rotating machinery.
Working Principle: In a three-phase system, three sinusoidal voltages of equal magnitude and frequency are generated, with each voltage phase-shifted by 120 degrees from the others. The standard phase sequence ensures that the voltages reach their peak values in a specific order (e.g., A first, then B, then C). If the phase sequence is changed (e.g., from ABC to ACB), the direction of rotation of the magnetic field in motors will reverse, which can cause the motor to run in the opposite direction.
Correct Option Analysis:
The correct option is:
Option 3: Phase current changes by angle but not by magnitude.
This option correctly describes the effect of changing the phase sequence on the phase currents in a three-phase system. When the phase sequence is altered, the phase currents will shift in phase angle by 120 degrees, but their magnitudes will remain unchanged. This is because the phase sequence change does not affect the amplitude of the sinusoidal currents, only their relative timing.
Detailed Explanation:
In a three-phase system, the voltage and current waveforms are typically represented as:
Original Phase Sequence (ABC):
- Phase A: VA(t) = Vmsin(ωt)
- Phase B: VB(t) = Vmsin(ωt - 120°)
- Phase C: VC(t) = Vmsin(ωt - 240°)
Here, Vm is the peak voltage, ω is the angular frequency, and t is time.
When the phase sequence changes from ABC to ACB, the voltage waveforms become:
- Phase A: VA(t) = Vmsin(ωt)
- Phase C: VC(t) = Vmsin(ωt - 120°)
- Phase B: VB(t) = Vmsin(ωt - 240°)
Consequently, the phase currents will also shift in phase angle by 120 degrees, but their magnitudes will remain the same. This shift in phase angle is crucial for devices that rely on the direction of the rotating magnetic field, such as induction motors, as it will cause them to rotate in the opposite direction.
Additional Information
To further understand the analysis, let’s evaluate the other options:
Option 1: Magnitude of phase power is changed.
This option is incorrect because the magnitude of the phase power in a balanced three-phase system does not depend on the phase sequence. Phase power is primarily determined by the voltage, current, and power factor. Changing the phase sequence only affects the direction of rotation of the magnetic field, not the magnitude of the power.
Option 2: Magnitude of phase current is changed.
This option is also incorrect because changing the phase sequence does not affect the magnitude of the phase currents. The phase currents will have the same amplitude but will be phase-shifted by 120 degrees.
Option 4: Total power consumed will change.
This option is incorrect because the total power consumed in a balanced three-phase system is the sum of the power consumed in each phase. Since the power in each phase remains unchanged regardless of the phase sequence, the total power consumed will also remain unchanged.
Conclusion:
Understanding the impact of phase sequence on three-phase systems is crucial for the correct operation of equipment, especially motors. Changing the phase sequence results in a phase shift of the currents by 120 degrees, but their magnitudes remain unchanged. This phase shift can reverse the direction of rotation of motors, which is essential information for ensuring the proper functioning of three-phase machinery.
Effect of Source Impedance on Converters Question 15:
A single phase full converter feeds power to RLE load with R = 8Ω, L = 8 mH and E = 46.42 V, the ac source voltage is 230 V, 50 Hz, for continuous conduction. Find the average value of load current for a firing angle delay of 45°
Answer (Detailed Solution Below)
Effect of Source Impedance on Converters Question 15 Detailed Solution
The average output voltage of a 1-ϕ full converter with RLE loads for continuous conduction.
\({V_0} = \frac{{2{V_m}}}{\pi }\cos \alpha\)
Vm = √2 Vrms = √2 x 230 V
V0\(= \frac{{2\; \times \;√ 2 \cdot 230}}{\pi }\cos 45^\circ\)
V0 = 146.42 V
V0 = E + I0R
\({I_0} = \frac{{{V_0} - E}}{R}\)
\(= \frac{{146.42 - 46.42}}{8}\)
I0 = 12.50 A